浏览全部资源
扫码关注微信
1. 中国科学院大学 北京,中国,100049
2. 中国科学院 长春光学精密机械与物理研究所, 吉林 长春 130033
3. 中国科学院苏州生物医学工程技术研究所,江苏 苏州,215000
收稿日期:2015-01-10,
修回日期:2015-02-06,
纸质出版日期:2015-12-05
移动端阅览
李铭, 卢彦飞, 袁刚等. 应用先验插值校正CT金属伪影[J]. 液晶与显示, 2015,30(6): 1032-1039
Li Ming, Lu Yan-fei, Yuan Gang etc. Metal artifact reduction in computed tomography based on prior interpolation[J]. , 2015,30(6): 1032-1039
李铭, 卢彦飞, 袁刚等. 应用先验插值校正CT金属伪影[J]. 液晶与显示, 2015,30(6): 1032-1039 DOI: 10.3788/YJYXS20153006.1032.
Li Ming, Lu Yan-fei, Yuan Gang etc. Metal artifact reduction in computed tomography based on prior interpolation[J]. , 2015,30(6): 1032-1039 DOI: 10.3788/YJYXS20153006.1032.
针对CT系统在实际应用中出现的金属伪影问题
提出一种基于先验插值的金属伪影校正算法。文中通过预滤波、骨骼分割和软组织恢复步骤计算先验图像
并利用先验图像的正向投影对原始投影中的金属投影区进行插值校正。应用该算法对数值仿真图像和临床CT图像分别进行了校正重建实验。数值仿真实验表明
用提出算法校正的结果比线性插值金属伪影校正算法、归一化金属伪影校正算法校正的结果更接近理想体模。临床数据实验表明:该算法的重建结果有效抑制了金属伪影
清晰重建出金属边缘细节
极大地提高了重建图像的质量。
Presence of metal artifacts in computed tomography (CT) is a major reason of degradation of image quality. In this work
a novel metal artifact reduction (MAR) algorithm using prior interpolation was developed to suppress metal artifacts in CT images. The prior image was generated by pre-filtering
bone extraction
and soft tissue restoring procedures. This prior image was then reprojected
and the estimation of surrogate data in the metal traces could be performed via the reprojections. Next
the corrected experiments were conducted on digital phantom and clinical data respectively. The simulation experiment shows that results stem from prior interpolation MAR (PI-MAR) have higher similarity of ideal phantom than those from linear-interpolation MAR (LI-MAR) and Normalized MAR (NMAR) algorithms. Clinical experimental results demonstrate that the new algorithm can successfully suppress metal artifacts and clearly restore anatomical structure close to metallic implants. Moreover
the quality of reconstructed images can be greatly improved by the proposed algorithm.
Robertson D D, Yuan J, Wang G, et al. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction[J]. Journal of Computer Assisted Tomography, 1997, 21(2):293-298.
李铭,张涛,郑健,等.基于切线反投影的CT金属位置和形状标定[J].液晶与显示, 2013,28(2):295-299. Li M, Zhang T, Zheng J, et al. Determination of location and shape of metallic object in CT based on tangent back-projection[J]. Chinese Journal of Liquid Crystals and Displays, 2013, 28(2):295-299. (in Chinese)
Kalender W A, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants[J]. Radiology, 1987, 164(2):576-577.
李印生,陈阳,马建华,等.基于自适应方向性滤波和非局部均值修补的CT图像金属伪影消除[J].中国生物医学工程学报, 2011,30(3):377-381. Li Y S, Chen Y, Ma J H, et al. Metal artifact reduction in CT based on adaptive steering filter and nonlocal sinogram inpainting[J]. Chinese Journal of Biomedical Engineering, 2011, 30(3):377-381. (in Chinese)
Gu J W, Zhang L, Chen Z Q, et al. A method based on interpolation for metal artifacts reduction in CT images[J]. Journal of X-Ray Science and Technology, 2006, 14(1):11-19.
Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering[J]. Medical Physics, 2006, 33(8):2852-2859.
Meyer E, Raupach R, Lell M, et al. Frequency split metal artifact reduction (FSMAR) in computed tomography[J]. Medical Physics, 2012, 39(4):1904-1916.
Lell M M, Meyer E, Kuefner M A, et al. Normalized metal artifact reduction in head and neck computed tomography[J]. Investigative Radiology, 2012, 47(7):415-421.
Oehler M, Buzug T M. The -MLEM algorithm:An iterative reconstruction technique for metal artifact reduction in CT images[J]. Advances in Medical Engineering, 2007, 114:42-47.
Boas F E, Fleischmann D. Evaluation of two iterative techniques for reducing metal artifacts in computed tomography[J]. Radiology, 2011, 259(3):894-902.
Zhang X M, Xing L. Sequentially reweighted TV minimization for CT metal artifact reduction[J]. Medical Physics, 2013, 40(7):071907.
Zhang Y B, Yan H, Jia X, et al. A hybrid metal artifact reduction algorithm for x-ray CT[J]. Medical Physics, 2013, 40(4):041910.
张宇洋,刘满华,韩韬.基于Mean Shift图像分割和支持向量机判决的候梯人数视觉检测系统[J].光学精密工程, 2013,21(4):1079-1085. Zhang Y Y, Liu M H, Han T. Elevator-waiting people counting system based on Mean Shift segmentation and SVM classification[J]. Optics and Precision Engineering, 2013, 21(4):1079-1085. (in Chinese)
Yu HY, Zeng K, Bharkhada D K, et al. A segmentation-based method for metal artifact reduction[J]. Academic Radiology, 2007, 14(4):495-504.
Jacobs F, Sundermann E, De Sutter B, et al. A fast algorithm to calculate the exact radiological path through a pixel or voxel space[J]. Journal of Computing and Information Technology, 1998, 6(1):89-94.
Boone J M, Seibert J A. An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV[J]. Medical Physics, 1997, 24(11):1661-1670.
La Rivire P J, Bian J G, Vargas P A. Penalized-Likelihood sinogram restoration for computed tomography[J]. IEEE Transactions on Medical Imaging, 2006, 25(8):1022-1036.