A portable multichannel bioelectrical signal processing system is proposed.Through electrode selection according to the actual needs
the system can collect
process
display and store EEG or ECG signal in real-time. Texas Instruments (TI) Company's ADS1198 is employed as the core for the analog front-end circuit
realizing EEG or ECG acquisition
amplification
isolation and other pretreatment operations. Altera Company's FPGA chip Cyclone Ⅱ EP2C70F896C6 is used for processing the data
displaying waveform in the LCD screen of TRBD_LTM.The system has high accuracy
small size
low power consumption
good practicality and scalability.
关键词
Keywords
references
陈颖莹. 德州仪器为ECG和EEG量身打造全面集成的模拟前端[J]. 电子技术应用, 2010(5):3-3. Chen Y Y.Texas instruments make comprehensive integrated analog front end for ECG and EEG.Electronic Technology Application, 2010(5):3-3.(in Chinese)[2] 魏厚杰, 官金安, 方浩. ADS1298模拟前端的便携式生理信号采集系统[J]. 单片机与嵌入式系统应用, 2012, 12(2): 36-39. Wei H J, Guan J A, Fang H.ADS1298 analog front end of a portable physiological signal acquisition system[J].Microcontroller and Embedded Systems Applications, 2012, 12(2):36-39.(in Chinese)[3] 凌朝东, 黄群峰, 张艳红, 等. 脑电信号提取专用电极芯片的设计[J]. 华侨大学学报, 2007, 28(3):260-263. Ling C D, Huang Q F, Zhang Y H, et al.Brain electrical signal extraction electrode chip design[J].Journal of Huaqiao University, 2007, 28(3):260-263.(in Chinese)[4] Huang X Y, Wan A, CHEN Z J.Development of EEG-based Intelligent Wheelchair Based on FPGA[J].The 1st Asia-Pacific Workshop on FPGA Applications, 2012, 1(1):79-91.[5] 张洪涛, 莫文承, 李兵兵. 基于SPI协议的SD卡读写机制与实现方法[J]. 电子元器件应用, 2008, 10(3):42-43, 47. Zhang H T, Mo W C, Li B B.Mechanism and implementation method of SD card reading and writing based on the SPI protocol[J].Electronic Component & Device Applications, 2008, 10(3):42-43, 47.(in Chinese)[6] TI.ADS1198 Datasheet[EB/OL].[2011-11].http://www.ti.com.cn/cn/lit/ds/symlink/ads1198.pdf.[7] Altera.TRDB_LTM User Manual[EB/OL].[2011-06].http://www.terasic.com.tw/cgi-bin/page/archive_download.pl Language=English&No=213&FID=b226168825c32dd5d7064e9a57f42b0b.[8] 凌朝东, 洪华峰, 李国刚, 等. 基于NIOS Ⅱ的便携式远程医疗监护器硬件平台的设计[J]. 仪器仪表学报, 2008, 29(2):336-341. Ling C D, Hong H F, Li G G, et al.Hardware design of portable telemedicine monitoring equipment based on NIOS Ⅱ soft-core[J].Chinese Journal of Scientific Instrument, 2008, 29(2): 336-341.(in Chinese)[9] 徐洋. 40Gsps 随机取样数字示波器关键技术预先研究[D].成都: 电子科技大学, 2004. Xu Y.The key technology research in advance 40 GSPS random sampling digital oscilloscope[D].Chengdu: University of Electronic Science and Technology of China, 2004.