邱西振, 张方辉, 丁磊, 张静. 粗化玻璃基板对OLED的影响[J]. 液晶与显示, 2012,(2): 168-172
QIU Xi-zhen, ZHANG Fang-hui, DING Lei, ZHANG Jing. Impact of Roughening Glass on OLED[J]. , 2012,(2): 168-172
为了对畸变波前进行精确校正
研究了液晶波前校正器在不同灰度级之间的动态位相响应特性,准确确定其响应时间。首先给出液晶波前校正器的响应时间和位相变化的检测方案。然后检测了液晶波前校正器在0和255灰度级之间的上升和下降时间,分别为7ms和11ms。在保证校正精度的条件下,对该位相曲线采取λ/10的误差截断,使上升和下降时间分别减少到4ms和6.8ms。最后,研究了各灰度级以次上升到255和从255再以次回落到各灰度级的动态响应时间。结果表明,各灰度级的上升时间在2ms-5.2ms之间变化,下降时间在3.66ms-8.74ms之间变化,且无论是上升还是下降,150和255灰度级之间转换速度最快,在255灰度级邻近的灰度响应速度最慢,且响应时间长于0和255灰度之间的响应时间。因此,在波前校正中,须以255灰度邻近的灰度级中最长的响应时间作为液晶波前校正器的响应时间,以确保波前校正精度。
To achieve the high accuracy correction of the distorted wavefront
dynamic phase response characteristic between different grey levels of liquid crystal wavefront correctors (LC WFCs) was investigated. First
a scheme was given to measure the response time and phase modulation of the LC WFC. Then
the fall and rise time of a LC WFC were measured between 0 and 255 grey levels. The results indicate the rise and fall time are 7ms and 11ms respectively. To assure the correction accuracy
the phase modulation curves were cut off with error of λ/10 (λ=633nm) and then the rise and fall time were reduced to 4ms and 6.8ms respectively. At last
the dynamic response time
which is produced with every other grey levels go up to 255 grey level and the reverse process
was measured. The measured results show that the rise and fall time of the grey levels vary at the range of 2ms-5.2ms and 3.7ms-8.7ms respectively. Simultaneously
the switching time between the grey level of 150 and 255 is shortest for both of the rise and fall time
and the response time is longest for the grey levels which is adjacent to 255 grey level. Furthermore
the response time of the grey levels nearby 255 grey level is larger than the response time between 0 and 255 grey level. Therefore
to assure the accurate correction of the wavefront
the response time of the LC WFC should be selected with the longest switch time among the grey levels which is adjacent to 255 grey level.