针对偏振式立体投影仪
研究了其左右光路不一致性及立体串扰度对立体投影质量的影响。屏幕上投影图像的不严格重合、两路光路在色度亮度上的差异以及偏振眼镜造成的立体串扰等都会影响最终的立体投影质量。提出用上述参数评价偏振式立体投影仪的立体投影质量并完成了评价系统的搭建。通过数字摄像头获取立体投影设备在屏幕上相应的投影图像
采用OpenCV等算法计算及分析了上述参数值
并将该值与预存的最大偏差值比较后进行显示及反馈。在一台偏振式立体投影仪上进行了系统验证
结果表明该系统能够有效地对立体投影仪性能参数进行测量及反馈
有利于全面分析偏振式立体投影仪的立体投影质量
便于提高投影仪的整体质量。
For polarized stereoscopic projector
the influence of two main performance para-meters
which are the inconsistency in color and brightness of the left and right optical paths and stereo crosstalk
on stereoscopic projection quality is studied. The stereoscopic projection quality will be influenced by a number of factors
which are two projection images not strictly coincident on the screen
two optical paths' difference in color and brightness
stereo crosstalk caused by the polarized glasses
etc. The evaluation method is presented to evaluate the stereoscopic projection quality according to those factors and the evaluation system is built. The system obtains projection images by a digital camera
those parameters were analyzed and calculated by OpenCV
and then were compared with the presented maximum deviation value
the comparison result were sent to display and feedback signal. The system function is verified by using a stereoscopic projector. The result indicates that the evaluation system can measure and feedback performance parameters of stereoscopic projector effectively
and help to analyze the stereoscopic projection quality of the polarized stereoscopic projector comprehensively
thus enhance the stereoscopic projection quality.
刘旭,李海峰. 现代投影显示技术 [M]. 杭州:浙江大学出版社, 2009.[2] 吕朝辉,徐丽丽,许鹏飞. 立体图像质量评价技术综述[J]. 电视技术, 2009,33(12):38-40.[3] Yu Z,Wu H R,Winkler S, et al. Vision-model-based impairment metric to evaluate blocking artifact in digital video[J]. Proceeding of IEEE, 2002, 90(1): 154-169.[4] Nill N B,Bouzas B H. Objective image quality measure derived from digital image power spectra[J]. IEEE Signal Processing Letter, 2002, 9(3): 388-392.[5] Wang Z,Alan C B,Hamid R S. Image quality assessment: from error visibility to structural similarity[J]. IEEE Transactions on Image Processing, 2004, 13(4): 600-612.[6] Salmimaa M,Jarvenpaa T. 3-D自由立体显示的性能表征[J]. 现代显示 ,2009,(11):5-8.[7] 温娜,李默. IEC立体显示终端测量方法综述[J]. 电视技术, 2011,35(4):75-77.[8] 潘冬冬,王琼华,李大海,等. 偏振眼镜立体显示的立体串扰度及其影响因素[J]. 光学技术, 2009,35(4):517-518.[9] Huang K C,Tsai C H,Lee K, et al.Measurement of contrast ratios for 3D display //Jnput/output and Imaging TechnologiesⅡ, Proceedings of SPIE, 2004,4080:78-86.[10] 傅鹏翔. 视觉检测系统基本原理及评判方法初析[J]. 自动化仪表, 2007,28(z1):136-141.[11] 佘佳音. 投影软幕畸变的检测与校正方法研究 . 长春:长春理工大学硕士学位论文,2010.[12] 马颂德, 张正友. 计算机视觉 [M]. 北京:科学出版社,1998.