Optimization of backlight scanning on auto-stereoscopic display with spatial and sequential hybrid control
Auto-Stereoscopic with improved spatial and sequential hybrid control (SSHC) is a new type of auto-stereoscopic display technology which retains full resolution and low crosstalk ratio. It eliminates the temporal crosstalk caused by the non-synchronization between the screen and the backlight module
which is one of the key issues of auto-stereoscopic display with SSHC. The paper explains principles of auto-stereoscopic display with SSHC and dynamic backlight system. Two different refreshing strategies of backlight module are introduced
which are the scanning type and the vertical type. Comparison on the influences on the luminance and crosstalk ratio of the display system for both strategies is mainly discussed. The optimal settings for backlight module are achieved through experimental results. Experimental results show that the crosstalk ratio of the display system can be suppressed as low as 2.64% with the optimal settings
which proves that the dynamic backlight control technique can effectively lowers temporal crosstalk.
关键词
Keywords
references
Liou J C, Lee K, Huang J F. Low crosstalk multi-view tracking 3-D display of synchro-signal LED scanning backlight system[J]. J. Display Technol., 2011, 7(8):411-419.[2] 王琼华.3D显示技术与器件[M].北京:科学出版社,2011:11-27. Wang Q H. 3D display Technology and Devices[M]. Beijing:Science Press, 2011:11-27. (in Chinese)[3] Son J Y, Javidi B, Yano S, et al. Recent developments in 3-D imaging technologies[J]. J. Display Technol., 2010, 6(10):394-403.[4] Peterka T, Kooima R, Sandin D, et al. Advances in the dynallax solid-state dynamic parallax barrier autostereoscopic visualization display system[J]. IEEE Trans. Vis. Comput. Graphics, 2008, 14(3):487-499.[5] Son J Y, Saveljev V V, Kim J S, et al. Viewing zones in 3-D imaging systems based on lenticular, parallax barrier and microlens array plates[J]. Appl. Opt., 2004, 43(26):4985-4992.[6] Chien K W and Shieh H P. Time-multiplexed three-dimensional displays based on directional backlights with fast-switching liquid-crystal displays[J]. Appl. Opt., 2006, 45:3106-3110.[7] Chen C H, Yeh Y C, Shieh H P. 3-D mobile display based on Moiré-free dual directional backlight and driving scheme for image crosstalk reduction[J]. J. Display Technol., 2008, 4(1):92-96.[8] 王嘉辉,邓玉桃,苏剑邦,等.全高清裸眼3D显示效果的评价与测量[J].液晶与显示,2013, 28(5):805-809. Wang J H, Deng Y T, Su J B. Evaluation and measurement of the display effect in full high resolution autostereoscopic display[J]. Chinese Journal of Liquid Crystals and Displays, 2013, 28(5):805-809. (in Chinese)[9] Kooi F L,Toet A. Visual comfort of binocular and 3D displays[J]. Displays, 2004, 25:99-108.[10] Wang J H, Liang H W, Fan H, et al. High-quality autostereoscopic display with spatial and sequential hybrid control[J]. Appl. Opt., 2013, 52(35):8549-8553.[11] 王嘉辉,邓玉桃,黎奕宁,等.眼镜式3D显示设备综合性能测试方案的研究[J].液晶与显示, 2014, 29(6):1071-1076. Wang J H, Deng Y T, Li Y N. Measurement and evaluation of comprehensive performance in 3D Display with glasses[J].Chinese Journal of Liquid Crystals and Displays, 2014, 29(6):1071-1076. (in Chinese)