DAI Qin, MAO You-ming, WU Kai-xuan, WU Jie, LI Ye-qiu. High speed and high precision time-interval measurement system in pulsed laser ranging[J]. , 2015,30(1): 83-87
DAI Qin, MAO You-ming, WU Kai-xuan, WU Jie, LI Ye-qiu. High speed and high precision time-interval measurement system in pulsed laser ranging[J]. , 2015,30(1): 83-87 DOI: 10.3788/YJYXS20153001.0083.
High speed and high precision time-interval measurement system in pulsed laser ranging
A high speed and high precision time-interval measurement system based on FPGA and TDC-GP21 was introduced in this paper. The high precision module of TDC-GP21 was used and by configuring TDC-GP21
the time-interval measurement and calibration are finished to improve the precision
and a multi-level FSM were designed to realize the SPI communication and reduce the measurement period. According to the analysis of the factors which affected the precision of measure and the drift error of three discriminators
a discriminator was designed to reduce the nonlinearity error of the system. The signal of FPGA and the signal of laser echo were also used to realize time-interval measurement and laser ranging. The experiment results showed that the good linearity and the measurement repetition rate of 1 kHz and the measuring precision of 100 ps can be achieved.
关键词
Keywords
references
黄军芬,黄民双,孙亚玲,等. 基于伪非均匀采样的高精度时间间隔测量方法[J]. 光电子·激光, 2012, 23(16):1945-1948. Huang J F, Huang M S, Sun Y L, et al.High precision time-interval measurement method based on pseudo-nanuniform sampling [J].Journal of Optoelectronics·Laser, 2012, 23(16):1945-1948.(in Chinese)[2] 宋建辉,袁峰,丁振良. 脉冲激光测距中高精度时间间隔的测量[J]. 光学精密工程, 2009, 17 (5):1046-1050. Song J H, Yuan F, Ding Z L. High precision time interval measurement in pulsed laser ranging [J]. Optics and Precision Engineering, 2009, 17 (5):1046-1050. (in Chinese)[3] 施智勇,潘晓声,张谦. 利用延时法进行高精度脉冲激光测距[J]. 光学精密工程, 2014,22(2):253-258. Shi ZY, Pan X S, Zhang Q. High-precision pulsed laser measuring distance by time delay method [J].Optics and Precision Engineering, 2014, 22(2): 253-258.[4] 陈瑞强 江月松. 脉冲激光测距的时间间隔测量方法[J]. 光学学报, 2013,33(2):0212004-1-0212004-5. Chen R Q, Jiang Y S. Method of measurement on time-interval in pulsed laser ranging [J].ACTA Optica Sinica 2013, 33(2):0212004-1-0212004-5.[5] 吴刚,李春来,刘银年. 脉冲激光测距系统中高精度时间间隔测量模块的研究[J]. 红外与毫米波学报, 2007, 26(3): 214-216. Wu G, Li C L, Liu Y N. Study on high resolution time interval measurement module in pulsed laser ranging system [J].Journal of Infrared And Millimeter Waves, 2007, 26(3): 214-216. (in Chinese)[6] 邢燕. 高精度时间间隔测量系统[J]. 电子测量技术, 2010, 33(5):1-3. Xing Y. High-precision time interval measurement system [J].Electronic Measurement Technology,2010, 33(5):1-3. (in Chinese)[7] 冯志辉,刘恩海,岳永坚. 基于FPGA延迟线插入法的半导体激光测距[J]. 光电工程, 2010, 37(4): 53-59. Feng Z H, Liu E H, Yue Y J. FPGA delay-line interpolation method for laser range finding [J].Opto-Electronic Engineering,2010, 37(4): 53-59. (in Chinese)[8] 张丽丽,傅江涛,张志勇,等. FPGA在远程激光测距中的应用[J]. 激光与红外, 2010, 40(3): 288-289. Zhang L L, Fu J T, Zhang Z Y, et al.Application of FPGA in long distance laser ranging [J].Laser & Infrared,2010, 40(3): 288-289. (in Chinese)[9] 冯国旭,常保成. 高精度激光测距技术研究[J]. 激光与红外, 2007 37(11):1137-1140. Feng G X, Chang B C. Study of high precision laser ranging technology [J].Laser & Infrared,2007 37(11):1137-1140. (in Chinese)[10] 纪荣祎,赵长明,任学成. 脉冲激光测距时刻鉴别方法的研究[J]. 激光与红外, 2010,31(11): 34-36. Ji R Y, Zhao C M, Ren X C. Study of timing discriminator for pulsed laser rangefinder [J].Laser & Infrared,2010,31(11): 34-36. (in Chinese)[11] 朱福,林一楠. 一种提高脉冲激光测距精度的方法[J]. 光电技术应用, 2011, 26(2):42-44. Zhu F, Lin Y N. Method to improve accuracy of pulse laser ranging [J].Electro-Optic Technology Application 2011,26(2):42-44. (in Chinese)