Analysis of frame rate matching of infrared scene simulation system based on DMD
Due to the special imaging features of digital micro-mirror device
the scene simulation system need to be addressed in the course of their work frame matching problem to avoid an image aliasing.The modulation characteristics of DMD chip pulse width and the effects that frame rate matches the simulation scene imaging system were analyzed. Through carrying out the system experiments in different display time and detector integration time
the frame matching condition of static scene simulation was obtained
which was that the phenomenon of image aliasing could be avoided when the detector integration time was integral multiple of the display time of simulation system without external synchronization trigger signal. This method can reduce the difficulty in engineering implementation
and it is also important to popularize the application of infrared scene simulation system.
关键词
Keywords
references
唐德帅,何永强,黄富瑜,等. 基于DMD的动态红外场景仿真技术研究[J]. 红外技术, 2012,34(8):476-481. Tang D S, He Y Q, Huang F Y,et al.Study on dynamic infrared scene simulation technique based on digital micro-mirror device[J].Infrared Technology,2012,34(8):476-481. (in Chinese)[2] 陈建华,朱明,黄德天. 数字微镜器件动态红外场景投影技术[J]. 中国光学与应用光学, 2010,3(4):325-336. Chen J H, Zhu M, Huang D T. Dynamic infrared scene projection technology based upon digital micromirror device[J].Chinese Journal of Optics and Applied Optics,2010,3(4):325-336. (in Chinese)[3] 胡华超,魏冰妍,胡伟,等. 动态掩膜光刻在液晶取向中的应用[J]. 液晶与显示, 2013,28(2):199-203. Hu H C, Wei B Y, Hu W,et al.Applications of dynamic mask based photolithography in liquid crystal alignment[J].Chinese Journal of Liquid Crystals and Displays,2013,28(2):199-203. (in Chinese)[4] 徐正平,王德江,黄厚田,等. 数字微镜器件视频显示性能分析[J]. 液晶与显示, 2013,28(2):255-260. Xu Z P, Wang D J, Huang H T,et al.Analysis on performance of video displaying system based on DMD[J].Chinese Journal of Liquid Crystals and Displays,2013,28(2):255-260. (in Chinese)[5] Dennis R P, James A. Carter Ⅲ digital mirror device infrared scene projector[J].SPIE,1994, 2223:75-86.[6] Brett B D, Bender M, Crosby J,et al.Advancements in the micromirror array projector technology II[J].SPIE,2005, 5785:68-79.[7] Easley D B, Bender M, Crosby J,et al.Dynamic infrared scene projectors based on DMD[J].SPIE,2009, 7210:0I/1-0I/2.[8] 张凯,孙嗣良. 红外动态场景目标模拟器系统设计[J]. 红外与激光工程, 2011,40(1):12-16. Zhang K, Sun C L. Design of infrared dynamic scene target simulator system[J].Infrared and Laser Enginee-ring,2011,40(1):12-16. (in Chinese)