浏览全部资源
扫码关注微信
北京京东方显示技术有限公司, 北京 100176
Received:19 January 2020,
Revised:10 March 2020,
Accepted:10 March 2020,
Published:05 September 2020
移动端阅览
Ping-qi ZHANG, Dan WANG, Zhen-hua LYU, et al. Review of determinants of healthy display[J]. Chinese journal of liquid crystals and displays, 2020, 35(9): 981-990.
Ping-qi ZHANG, Dan WANG, Zhen-hua LYU, et al. Review of determinants of healthy display[J]. Chinese journal of liquid crystals and displays, 2020, 35(9): 981-990. DOI: 10.37188/YJYXS20203509.0981.
针对显示行业对健康显示的持续关注,本文较为系统地分析了不同显示要素可能对人眼产生的影响。从行业角度出发,阐释了对健康显示概念的理解。现有显示要素如蓝光、偏振光、频闪、眩光等对人眼可能产生潜在的影响。健康显示不同于单纯以提升产品性能为主要指标,而是更多地从系统角度出发,聚焦用户主体。通过用户与产品的使用交互,显示产品能够根据用户需求,实现智能化输出,使用户能够以良好的习惯使用,实现生理和心理上的舒适为目的。最后,从行业角度对面板技术开发和产业联动进行了初步思考。
As the display industry continues to focus on healthy display
how different factors may affect the human eye were investigated systematically. The paper explains the concept of healthy display. The summary shows that different factors like blue-light
polarized light
flicker
dazzle may affect the human eye. Healthy display doesn't simply focus on product performance
but pay more attention to the user's experience from the system perspective. Through the interaction between the user and the product
the display product can realize the intelligent output according to the user's needs
and when the user uses it with good habits
it can achieve both physical and psychological comfort. Finally
the development and promotion strategies are discussed.
李 继军 , 聂 晓梦 , 甄 威 , 等 . 显示技术比较及新进展 . 液晶与显示 , 2018 . 33 ( 1 ): 74 - 84 . http://cjlcd.lightpublishing.cn/thesisDetails?columnId=1377207&Fpath=&index=-1&l=zh http://cjlcd.lightpublishing.cn/thesisDetails?columnId=1377207&Fpath=&index=-1&l=zh .
J J LI , X M NIE , C ZHEN , 等 . New developments and comparisons in display technology . Chinese Journal of Liquid Crystals and Displays , 2018 . 33 ( 1 ): 74 - 84 . http://cjlcd.lightpublishing.cn/thesisDetails?columnId=1377207&Fpath=&index=-1&l=zh http://cjlcd.lightpublishing.cn/thesisDetails?columnId=1377207&Fpath=&index=-1&l=zh .
杨 培增 , 范 先群 . 眼科学 , : 北京 人民卫生出版社 , 2018 . 5 - 25 .
P Z YANG , X Q FAN . Ophthalmology , : Beijing People's Medical Publishing House , 2018 . 5 - 2 .
F W CAMPBELL , R W GUBISCH . Optical quality of the human eye . The Journal of Physiology , 1966 . 186 ( 3 ): 558 - 578 . DOI: 10.1113/jphysiol.1966.sp008056 http://doi.org/10.1113/jphysiol.1966.sp008056 .
D M BERSON , F A DUNN , M TAKAO . Phototransduction by retinal ganglion cells that set the circadian clock . Science , 2002 . 295 ( 5557 ): 1070 - 1073 . DOI: 10.1126/science.1067262 http://doi.org/10.1126/science.1067262 .
申 崇渝 , 徐 征 , 赵 谡玲 , 等 . LED蓝光泄露安全性研究 . 光谱学与光谱分析 , 2014 . 34 ( 2 ): 316 - 321 . http://d.wanfangdata.com.cn/Periodical/gpxygpfx201402007 http://d.wanfangdata.com.cn/Periodical/gpxygpfx201402007 .
C Y SHEN , Z XU , S L ZHAO , 等 . Study on the safety of blue light leak of LED . Spectroscopy and Spectral Analysis , 2014 . 34 ( 2 ): 316 - 321 . http://d.wanfangdata.com.cn/Periodical/gpxygpfx201402007 http://d.wanfangdata.com.cn/Periodical/gpxygpfx201402007 .
Harvard Medical School. Blue light has a dark side[EB/OL].[2012-05-01] . http://www.health.harvard.edu/staying-healthy/blue-light-has-a-dark-side http://www.health.harvard.edu/staying-healthy/blue-light-has-a-dark-side .
B F GODLEY , F A SHAMSI , F Q LIANG , 等 . Blue light induces mitochondrial DNA damage and free radical production in epithelial cells . Journal of Biological Chemistry , 2005 . 280 ( 22 ): 21061 - 21066 . DOI: 10.1074/jbc.M502194200 http://doi.org/10.1074/jbc.M502194200 DOI: 10.1074/jbc.M502194200 http://doi.org/10.1074/jbc.M502194200 .
DUNBAR M, MELTON R. The lowdown on blue light: good vs bad, and its connection to AMD[EB/OL].[2020-01-19] . http://www.review of optometry.com/continuing education http://www.reviewofoptometry.com/continuingeducation .
International ElectroTechnical Commission. IEC/TR 62778-2014 Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires[S]. Switzerland: IEC, 2014.
闫 晓林 , 付 东 , 朱 昌昌 , 等 . 圆偏振光液晶电视对视疲劳的影响 . 中国预防医学杂志 , 2009 . 10 ( 8 ): 798 - 801 . http://www.cqvip.com/Main/Detail.aspx?id=31454118 http://www.cqvip.com/Main/Detail.aspx?id=31454118 .
X L YAN , D FU , C C ZHU , 等 . Effect of circularly polarized liquid crystal TV on visual fatigue . China Preventive Medicine , 2009 . 10 ( 8 ): 798 - 801 . http://www.cqvip.com/Main/Detail.aspx?id=31454118 http://www.cqvip.com/Main/Detail.aspx?id=31454118 .
张 莉 , 徐 亮 , 张 运红 , 等 . 应用眼动仪评价观看线偏光液晶电视与圆偏光液晶电视诱导的视疲劳研究 . 眼科 , 2016 . 25 ( 1 ): 63 - 67 . http://www.cnki.com.cn/Article/CJFDTotal-YAKE201601026.htm http://www.cnki.com.cn/Article/CJFDTotal-YAKE201601026.htm .
L ZHANG , L XU , Y H ZHANG , 等 . Study on human visual fatigue induced by watching linear polarized liquid crystal display and circular polarized liquid crystal display with eye tracker . Ophthalmology in China , 2016 . 25 ( 1 ): 63 - 67 . http://www.cnki.com.cn/Article/CJFDTotal-YAKE201601026.htm http://www.cnki.com.cn/Article/CJFDTotal-YAKE201601026.htm .
W A SHURCLIFF . Haidinger's brushes and circularly polarized light . Journal of the Optical Society of America , 1955 . 45 ( 5 ): 399 DOI: 10.1364/JOSA.45.000399 http://doi.org/10.1364/JOSA.45.000399 .
B F HOCHHEIMER , H A KUES . Retinal polarization effects . Applied Optics , 1982 . 21 ( 21 ): 3811 - 3818 . DOI: 10.1364/AO.21.003811 http://doi.org/10.1364/AO.21.003811 .
E DODT , M KUBA . Visually evoked potentials in response to rotating plane-polarized blue light . Ophthalmic Research , 1990 . 22 ( 6 ): 391 - 394 . DOI: 10.1159/000267052 http://doi.org/10.1159/000267052 .
X L YAN , D FU , C C ZHU , 等 . Invited paper :the circular polarized LCD-TV and its advantage over visual fatigue . SID Symposium Digest of Technical Papers , 2009 . 40 ( 1 ): 536 - 539 . DOI: 10.1889/1.3256836 http://doi.org/10.1889/1.3256836 .
时 粉周 , 王 珏 , 包 德海 . 照明光源的频闪对视功能的影响 . 中华航海医学与高气压医学杂志 , 2001 . 8 ( 2 ): 72 - 74 . http://www.cnki.com.cn/Article/CJFDTotal-ZHHH200102001.htm http://www.cnki.com.cn/Article/CJFDTotal-ZHHH200102001.htm .
F Z SHI , Y WANG , D H BAO . The effects of illumination light source's frequency flicker on vision function . Chinese Journal of Nautical Medicine and Hyperbaric Medicine , 2011 . 8 ( 2 ): 72 - 74 . http://www.cnki.com.cn/Article/CJFDTotal-ZHHH200102001.htm http://www.cnki.com.cn/Article/CJFDTotal-ZHHH200102001.htm .
Standards Committee of the IEEE Power Electronics Society. 1789-2015 IEEE recommended practices for modulating current in high-brightness LEDs for mitigating health risks to viewers[S]. New York: IEEE, 2015.
王莹.不同显示技术与照明环境对视疲劳影响研究[D].南京: 东南大学, 2018.
WANG Y.Study on the visual fatigue caused by display technology and ambient illumination[D]. Nanjing: Southeast University, 2018. (in Chinese)
中华人民共和国工业和信息化部.SJ/T 11343-2015数字电视液晶显示器通用规范[S].北京: 工业电子出版社, 2015.
Ministry of Industry and Information Technology. SJ/T 11343-2015 General specification for digital television LCD displays[S]. Beijing: Publishing House of Electronics Industry, 2015.
杜 红艳 , 李 兰根 , 杜 鹏程 , 等 . 视屏终端综合征与干眼症关系的研究 . 国际眼科杂志 , 2009 . 9 ( 10 ): 1999 - 2000 . http://www.cnki.com.cn/Article/CJFDTotal-GJYK200910065.htm http://www.cnki.com.cn/Article/CJFDTotal-GJYK200910065.htm .
H Y DU , L G LI , P C DU , 等 . Relationship between visual display terminals syndrome and dry eye syndrome . International Journal of Ophthalmology , 2009 . 9 ( 10 ): 1999 - 2000 . http://www.cnki.com.cn/Article/CJFDTotal-GJYK200910065.htm http://www.cnki.com.cn/Article/CJFDTotal-GJYK200910065.htm .
M A CONTÍN , M M BENEDETTO , M L QUINTEROS-QUINTANA , 等 . Light pollution:the possible consequences of excessive illumination on retina . Eye , 2015 . 30 ( 2 ): 255 - 263 . http://smartsearch.nstl.gov.cn/paper_detail.html?id=318e9536495f77fde19f7eab9864318d http://smartsearch.nstl.gov.cn/paper_detail.html?id=318e9536495f77fde19f7eab9864318d .
魏 娜 , 张 为冬 . 3D电视视差舒适度客观评价 . 现代电视技术 , 2014 . ( 4 ): 106 - 110 . http://cpfd.cnki.com.cn/Article/CPFDTOTAL-EXGZ201409003001.htm http://cpfd.cnki.com.cn/Article/CPFDTOTAL-EXGZ201409003001.htm .
N WEI , W D ZHANG . Objective evaluation of parallax comfort of 3D TV . Advanced Television Engineering , 2014 . ( 4 ): 106 - 110 . http://cpfd.cnki.com.cn/Article/CPFDTOTAL-EXGZ201409003001.htm http://cpfd.cnki.com.cn/Article/CPFDTOTAL-EXGZ201409003001.htm .
S YANO , S IDE , T MITSUHASHI , 等 . A study of visual fatigue and visual comfort for 3D HDTV/HDTV images . Displays , 2002 . 23 ( 4 ): 191 - 201 . DOI: 10.1016/S0141-9382(02)00038-0 http://doi.org/10.1016/S0141-9382(02)00038-0 .
N HIRUMA , T FUKUDA . Accommodation response to binocular stereoscopic TV images and their viewing conditions . SMPTE Journal , 1993 . 102 ( 12 ): 1137 - 1140 . DOI: 10.5594/J01656 http://doi.org/10.5594/J01656 .
LIU Y Z, WANG F, WANG C S. The research on visual fatigue factor in stereoscopic image observation[C]// Proceedings of the 2009 IEEE 10th International Conference on Computer-Aided Industrial Design & Conceptual Design . Wenzhou: IEEE, 2009: 1882-1887.
毛 苗 , 秦 开怀 . 3-D视频的视差优化调整方法 . 清华大学学报:自然科学版 , 2014 . 54 ( 10 ): 1356 - 1361 . http://www.cqvip.com/QK/93884X/201410/663773740.html http://www.cqvip.com/QK/93884X/201410/663773740.html .
M MAO , K H QIN . Disparity adjustment method for stereoscopic 3-D video . Journal of Tsinghua University:Science and Technology , 2014 . 54 ( 10 ): 1356 - 1361 . http://www.cqvip.com/QK/93884X/201410/663773740.html http://www.cqvip.com/QK/93884X/201410/663773740.html .
金 帅 , 邢 丽冬 , 钱 志余 , 等 . 3D影片中深度信息与观看者疲劳度的关联研究 . 中国生物医学工程学报 , 2014 . 33 ( 3 ): 306 - 312 . http://www.cqvip.com/QK/90680X/20143/661620934.html http://www.cqvip.com/QK/90680X/20143/661620934.html .
S JIN , L D XING , Z Y QIAN , 等 . The association between depth information of 3D movie and viewer fatigue . Chinese Journal of Biomedical Engineering , 2014 . 33 ( 3 ): 306 - 312 . http://www.cqvip.com/QK/90680X/20143/661620934.html http://www.cqvip.com/QK/90680X/20143/661620934.html .
C RECHICHI , L SCULLICA . Asthenopia and monitor characteristics . Journal Français d'Ophtalmologie , 1990 . 13 ( 8/9 ): 456 - 460 . http://www.ncbi.nlm.nih.gov/pubmed/2081858 http://www.ncbi.nlm.nih.gov/pubmed/2081858 .
P PENTLANDA . A new sense for depth of field . IEEE Transactions on Pattern Analysis and Machine Intelligence , 1987 .
石国忠. 3D观看中的视觉疲劳研究[D].北京: 北京邮电大学, 2015.
SHIG Z.The research of visual fatigue in 3-D viewing environment[D]. Beijing: Beijing University of Posts and Telecommunications, 2015. (in Chinese)
王凤姣.三维视频视觉疲劳的研究[D].北京: 北京邮电大学, 2014.
WANG F J.The research of visual fatigue for stereoscopic videos[D]. Beijing: Beijing University of Posts and Telecommunications, 2014. (in Chinese)
0
Views
98
下载量
6
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621