图1 实验流程图
Received:06 October 2022,
Revised:27 October 2022,
Published:05 September 2023
Scan QR Code
Cite this article
The combined measurement methods of subjective questionnaires, ECG signals, eye movement signals and ophthalmological parameters are used to study the effect of different types of display modes on visual fatigue of 2D and 3D TVs. The results show that the relative changes of BCDVA, TBUT, pupil diameter and Shannon entropy after watching 3D mode are significantly greater than those after watching 2D mode. Differences in relative RR interval values and heart rate (HR) induced by viewing 2D and 3D modes gradually increase after 50 min. Different types of display modes have different effects on subjective scoring symptoms, ophthalmological parameters, ECG parameters and eye movement parameters. The visual fatigue caused by watching 3D mode is greater than that caused by watching 2D mode, especially after watching 2D/3D mode 50 min, which has reference value for 3D movie production.
display mode;
heart rate variability;
eye movement;
stereo display;
visual fatigue
随着显示技术的发展,三维显示广泛应用于军事、健康、科研和教育等领域,特别是虚拟现实、增强现实和全息显示技术给用户带来全新的立体感和沉浸感[
客观评价方法主要借助先进的仪器设备测量相关的生理参数变化。Yuan等人把客观测量方法分为基于非接触式生理信号的测量方法和基于接触式生理信号的测量方法[
主观测量和客观评价方法各有优缺点,其中主观测量方法比较简单,易于采集,但是时间分辨率低,无法实时评价观看者的反应,且受个体差异影响比较大;客观评价可以被自动化,并告诉我们更多有关不适的生理原因,获得的数据更加准确,但是分析复杂。现有的二维和三维显示视疲劳测量研究大多基于单一模态测量观看前后的视疲劳状态,且没有相关的实验环境和观看设备的标准,因而仍没有一致的研究结论。
本文采用主观问卷测量和客观测量(ECG、眼动参数、视功能参数)相结合的测量方法,探究了观看70 min 2D和3D显示前后以及观看过程中的视疲劳变化情况。
本实验选取2D和3D左右格式的《阿凡达》视频作为刺激材料,采用分辨率为1 920×1 080的1 269 mm×799 mm索尼BRAVIA液晶显示屏为研究载体。该显示屏最高白场亮度为220 cd/m2。为了避免光环境对实验结果产生影响,本实验在无照明环境的实验室(照度<1 lx)内进行。
采用RT-5100综合验光仪、Pelli-Robson敏感度表、自制测量调节近点和集合近点设备、裂隙灯显微镜(型号:YZ5X)测量视功能参数。
采用BIOPAC公司生产的MP150多导生理记录仪采集心电数据,SMI公司生产的红外遥感眼动设备测量眼动参数。
主观问卷采用5级评分标准(5:程度严重,4:程度明显,3:程度中等,2:程度轻微,1:无)对“眼睛感觉不舒适”、“远近调节缓慢”、“眼睛疲劳”、“眼睛酸”、“眼干”、“头疼”和“头晕”等7个症状进行打分。
根据国际电信联盟发布的ITU-R BT.500-11标准《电视画面质量的主观评价方法》[
17名东南大学学生(14男3女,年龄24.4±1.46岁)参与本实验。受试者纳入标准包括双眼矫正后视力达到1.0及以上,无色弱,无色盲,无双眼视功能障碍。为了保证实验数据准确,要求受试者在实验前24 h内有高质量的睡眠,并且禁食含有酒精和咖啡因的食物。
所有受试者都参与观看2D和3D显示实验。每名受试者的两部分实验分别在不同日期的9:00~12:00或14:00~17:00进行,且观看2D和3D显示顺序是随机的。介绍完实验内容后,受试者自愿签署知情同意书,实验内容和流程均符合赫尔辛基宣言要求。
在实验开始前,告知受试者实验流程和实验过程中注意事项。整个实验流程如
图1 实验流程图
Fig.1 Schematic of experiment procedure
(1)填写主观问卷;
(2)测量1:包括视功能参数和微眼跳参数;
(3)为了采集观看电影前的眼动参数和心电参数,同步采集阅读5 min历史题材类电子书(定义为TE1)的心电信号和眼动信号;
(4)采集观看70 min 2D/3D显示的心电信号,其中观看电影前5 min和后5 min分别定义为TM1和TM2,其中TM1时间段的心电信号作为研究心电信号随时间变化的参考信号;
(5)再次同步采集阅读5 min电子书(定义为TE2)的眼动和心电信号;
(6)测量2:包括微眼跳参数和视功能参数;
(7)最后填写主观问卷,实验结束。
视功能参数主要包括最佳矫正远视力(Best Corrected Distance Visual Acuity,BCDVA)、最佳矫正近视力(Best Corrected Near Visual Acuity,BCNVA)、调节近点(Near Point Accommodation,NPA)、集合近点(Near Point Convergence,NPC)、对比敏感度(Contrast Sensitivity Frequency,CSF)和泪膜破裂时间(Tear Film Break-up Time,TBUT)。眼动参数主要包括注视期间的瞳孔大小(Ebook Mean Pupil Diameter,EMPD)、微眼跳期间的瞳孔大小(Microsaccade Mean Pupil Diameter,MMPD)、眨眼频率(Blink Frequency, BF)、扫视数目(Saccade Count, SC)和扫视速度(Saccade Velocity,SC)等。心电参数主要包括RR间期值(R-peak to R-peak interval,RR)、心率(HR)、低频功率(0.04~0.15 Hz,Low Frequency Power,LF Power)、高频功率(0.15~0.4 Hz,High Frequency Power,HF Power)、低频/高频比(LF/HF)和香农熵(Shannon Entropy)等生理参数。
图2 实验情况示意图
Fig.2 Schematic diagram of experiment
为了研究观看2D和3D显示前后视疲劳变化情况以及显示模式对各测量参数的影响,我们使用软件SPSS 16.0对观看2D和3D显示前后的测量参数分别进行配对样本T检验分析,然后将有显著变化的参数的相对变化值(观看后和观看前的差值除以观看前的值)作为因变量,显示模式等作为自变量,受试者作为随机变量进行ANOVA(Analysis of Variance)分析;选取p<0.05为差异有统计学意义,使用偏Eta方(Partial eta squared, η
配对样本T检验结果表明,观看2D和3D显示前后的BCDVA(2D/3D:p<0.001)、BCNVA(2D:p=0.001;3D:p<0.001)、CSF(2D/3D:p<0.001)和TBUT(2D/3D:p<0.001)都有显著的变化。从
图3 观看2D和3D显示前后视功能参数。(a) BCDVA;(b) BCNVA;(c) CSF;(d) TBUT的平均值。误差条表示标准差(**表示p<0.01)。
Fig.3 Mean values of ophthalmological parameters before and after watching 2D and 3D display modes. (a) BCDVA; (b) BCNVA; (c) CSF; (d) TBUT. Error bars indicate standard deviation(**:p<0.01).
将BCDVA相对变化量(R_BCDVA)、BCNVA相对变化量(R_BCNVA)、CSF相对变化量(R_CSF)和TBUT相对变化量(R_TBUT)分别作为因变量,显示模式作为自变量,受试者作为随机变量进行ANOVA分析,结果表明显示模式只对R_BCDVA(F1,16=10.79,p=0.005,η2p=0.40)和R_TBUT(F1,16=29.89,p<0.001,η2p=0.65)有显著影响且效应较大。
图4 视功能参数(a) R_BCDVA和(b) R_TBUT在2D和3D显示模式下的平均值及标准差(**表示p<0.01)。
Fig.4 Mean values and standard deviation of (a) R_ BCDVA and (b) R_TBUT under 2D and 3D display modes(**:p<0.01).
观看2D和3D显示前后眼动参数的配对样本T检验结果表明,观看2D和3D显示前后微眼跳期间的瞳孔直径MMPD(p<0.001)有显著的变化。
图5 观看2D和3D显示前后MMPD的平均值。误差条表示标准差(**表示p<0.01)。
Fig.5 Mean values of MMPD before and after watching 2D and 3D display. Error bars indicate standard deviation(**:p<0.01).
将MMPD的相对变化量(R_MMPD)作为因变量,显示模式作为自变量,受试者作为随机变量进行ANOVA分析,结果表明显示模式对R_MMPD有显著影响且效应较大(F1,16=31.27,p<0.001,η
图6 R_MMPD在2D和3D显示模式下的平均值及标准差(**表示p<0.01)。
Fig.6 Mean values and standard deviation of R_MMPD under 2D and 3D display modes(**:p<0.01).
观看2D和3D显示前后阅读5 min电子书的TE1和TE2时间段心电信号的配对样本T检验结果表明,观看2D显示前后的LF Power(ms2) (p=0.009)、HF Power(%)(p=0.001)和观看3D显示前后的LF Power(ms2)(p=0.003)、HF Power(%)(p=0.006)、Shannon Entropy(p=0.008)有显著的变化。
图7 观看2D和3D显示前后阅读电子书期间心电参数的平均值。(a) LF Power(ms2);(b) HF Power(%);(c) Shannon Entropy。误差条表示标准差(**表示p<0.01)。
Fig.7 Mean values of ECG parameters before and after watching 2D and 3D display modes during E-book reading. (a) LF Power(ms2); (b) HF Power(%); (c) Shannon Entropy. Error bars indicate standard deviation(**:p<0.01).
上述LF Power(ms2)相对变化量(R_LF Power(ms2)_1)、HF Power(%)相对变化量(R_HF Power(%))和Shannon Entropy相对变化量(R_Shannon Entropy)分别作为因变量,显示模式作为自变量,受试者作为随机变量进行ANOVA分析,结果表明显示模式仅对R_Shannon Entropy有显著影响且效应较大(F1,16=8.99,p=0.01,η
图8 R_Shannon Entropy在2D和3D显示模式下的平均值及标准差(*表示p<0.05)。
Fig.8 Mean values and standard deviation for R_Shannon Entropy under 2D and 3D display modes(*:p<0.05).
观看2D和3D显示前后7个主观症状配对样本T检验结果表明,“眼睛感觉不舒适”(p<0.001)、“眼睛疲劳”(p=0.004)和“眼睛酸”(p=0.001)在观看2D显示前后有显著变化;“眼睛感觉不舒适”(p<0.001)、“眼睛疲劳”(p<0.001)、“眼睛酸”(p=0.004)、“眼干”(p=0.001)、“远近调节缓慢”(p<0.05)和“头晕”(p<0.05)在观看3D显示前后有显著变化。
图9 观看(a) 2D和(b) 3D显示前后主观症状的分数平均值。误差条表示标准差(**表示p<0.01,*表示p<0.05)。
Fig.9 Mean values of subjective symptoms score before and after watching (a) 2D and (b) 3D display. Error bars indicate standard deviation(**:p<0.01;*:p<0.05).
将上述配对样本T检验有显著变化的主观症状打分的相对变化量作为因变量,显示模式作为自变量,受试者作为随机变量进行ANOVA分析,结果表明显示模式只对症状“眼睛疲劳”相对变化量(R_眼睛疲劳:F1,16=5.13,p=0.037,η
图10 观看2D和3D显示前后主观症状分数相对值的平均值和标准差(*表示p<0.05)。
Fig.10 Mean values and standard deviation for relative subjective symptoms score before and after watching 2D and 3D display(*:p<0.05).
为了研究显示模式、观看时间对心电参数的影响,我们将观看2D/3D显示期间前5 min(TM1时间段)的心电数据作为参考值,以各5 min数据段相对变化量(对应时间段的数据减去参考值然后再除以参考值)作为因变量,显示模式和时间作为自变量,受试者作为随机变量进行ANOVA分析。
因变量 | 自变量 | 统计检验量F | 显著性水平Sig. | 效应量η2p |
---|---|---|---|---|
R_RR | 时间 | 2.31 | 0.006 | 0.07 |
显示模式 | 11.30 | <0.005 | 0.03 | |
R_HR | 时间 | 2.79 | <0.005 | 0.09 |
显示模式 | 12.59 | <0.001 | 0.03 | |
R_LF Power(ms2) | 时间 | 2.56 | <0.005 | 0.08 |
显示模式 | 11.99 | 0.001 | 0.03 |
图11 观看2D和3D显示期间心电参数(a) R_RR、(b) R_HR和(c) R_LF Power(ms2)随时间变化趋势。误差条表示标准差(*表示p<0.05)。
Fig.11 Trend of (a) R_RR, (b) R_HR and (c) R_LF Power(ms2) over time during watching 2D and 3D display. Error bars indicate standard deviation(*:p<0.05).
视功能参数BCDVA、BCNVA和CSF定义视觉空间分辨率,反映一定距离内人眼辨别物体细节的能力。既往研究表明,视觉疲劳与人类通过双眼视觉编码视觉细节的能力有关[
眼动参数结果表明,注视(微眼跳)期间的瞳孔大小在观看电影前后有显著变化,既往研究也表明瞳孔直径随着视疲劳增加而变大[
心电信号受自主神经系统调节,代表心脏对各种环境刺激的反应能力。既往研究[
主观问卷中“眼干”症状增加和视功能参数TBUT缩短相一致,表明主观症状和客观视功能参数有很高的相关性。
此外,从观看70 min电影期间心率变异性参数变化可以看出,50 min以后2D和3D显示引起的R_RR和R_HR的差异逐渐增加。Ramadan等人通过测量心电参数和皮电参数发现,在近距离观看3D显示50 min后,身体压力显著增大,并随着观看时间的持续增加而增大,与本文结果相一致[
本文采用主观问卷测量和客观测量相结合的评价方法,在暗环境下研究2D和3D显示对视疲劳的影响。结果表明,观看3D显示后BCDVA和TBUT减小的百分比、香农熵、瞳孔直径、主观症状“眼睛疲劳”和“眼干”增加的百分比均显著大于观看2D显示,说明观看3D显示引起的视疲劳程度大于观看2D显示。通过心率变异性参数变化可以看出,50 min以后2D和3D显示引起的视疲劳程度逐渐增大,这个时间点对于3D电影制作商具有指导意义。未来的研究我们将继续增加受试者数量和3D景深程度,形成更加具有普适性的评估模型和结论。
PI D P, LIU J, WANG Y T. Review of computer-generated hologram algorithms for color dynamic holographic three-dimensional display [J]. Light: Science & Applications, 2022, 11(1): 231. doi: 10.1038/s41377-022-00916-3 [Baidu Scholar]
XIONG J H, WU S T. Planar liquid crystal polarization optics for augmented reality and virtual reality: from fundamentals to applications [J]. eLight, 2021, 1(1): 3. doi: 10.1186/s43593-021-00003-x [Baidu Scholar]
BLANCHE P A. Holography, and the future of 3D display [J]. Light: Advanced Manufacturing, 2021, 2(4): 446-459. doi: 10.37188/lam.2021.028 [Baidu Scholar]
张平奇,王丹,吕振华,等. 健康显示的影响因素综述[J]. 液晶与显示,2020,35(9):981-990. doi: 10.37188/YJYXS20203509.0981 [Baidu Scholar]
ZHANG P Q, WANG D, LYU Z H, et al. Review of determinants of healthy display [J]. Chinese Journal of Liquid Crystals and Displays, 2020, 35(9): 981-990. (in Chinese). doi: 10.37188/YJYXS20203509.0981 [Baidu Scholar]
朱念芳,屠彦,王莉莉,等. LCD手机白场亮度和饱和度对视觉舒适度和视疲劳的影响[J]. 液晶与显示,2022,37(8):1008-1021. doi: 10.37188/cjlcd.2022-0073 [Baidu Scholar]
ZHU N F, TU Y, WANG L L, et al. Influence of white level and color saturation of LCD smartphone on visual comfort and visual fatigue [J]. Chinese Journal of Liquid Crystals and Displays, 2022, 37(8): 1008-1021. (in Chinese). doi: 10.37188/cjlcd.2022-0073 [Baidu Scholar]
冯永,朱淑丰,陈霏. 视疲劳主观测量研究发展综述[J]. 中国生物医学工程学报,2021,40(5):597-607. doi: 10.3969/j.issn.0258-8021.2021.05.11 [Baidu Scholar]
FENG Y, ZHU S F, CHEN F. A review on the development of subjective evaluation of visual fatigue [J]. Chinese Journal of Biomedical Engineering, 2021, 40(5): 597-607. (in Chinese). doi: 10.3969/j.issn.0258-8021.2021.05.11 [Baidu Scholar]
SHEEDY J E, HAYES J, ENGLE J. Is all asthenopia the same? [J]. Optometry and Vision Science, 2003, 80(11): 732-739. doi: 10.1097/00006324-200311000-00008 [Baidu Scholar]
IRIBARREN R, FORNACIARI A, HUNG G K. Effect of cumulative nearwork on accommodative facility and asthenopia [J]. International Ophthalmology, 2001, 24(4): 205-212. doi: 10.1023/a:1022521228541 [Baidu Scholar]
MANGIONE C M, LEE P P, PITTS J, et al. Psychometric properties of the National Eye Institute visual function questionnaire (NEI-VFQ) [J]. Archives of Ophthalmology, 1998, 116(11): 1496-1504. doi: 10.1001/archopht.116.11.1496 [Baidu Scholar]
AMES S L, WOLFFSOHN J S, MCBRIEN N A. The development of a symptom questionnaire for assessing virtual reality viewing using a head-mounted display [J]. Optometry and Vision Science, 2005, 82(3): 168-176. doi: 10.1097/01.opx.0000156307.95086.6 [Baidu Scholar]
HEIDEN M, ZETTERBERG C, LINDBERG P, et al. Validity of a computer-based risk assessment method for visual ergonomics [J]. International Journal of Industrial Ergonomics, 2019, 72: 180-187. doi: 10.1016/j.ergon.2019.05.006 [Baidu Scholar]
TERZIC K, HANSARD M. Causes of discomfort in stereoscopic content: a review [J/OL]. arXiv, 2017: 1703.04574. [Baidu Scholar]
YUAN Z Y, ZHUO K, ZHANG Q, et al. Probabilistic assessment of visual fatigue caused by stereoscopy using dynamic Bayesian networks [J]. Acta Ophthalmologica, 2019, 97(3): e435-e441. doi: 10.1111/aos.13784 [Baidu Scholar]
ZHENG F H, HOU F, CHEN R R, et al. Investigation of the relationship between subjective symptoms of visual fatigue and visual functions [J]. Frontiers in Neuroscience, 2021, 15: 686740. doi: 10.3389/fnins.2021.686740 [Baidu Scholar]
WANG C A, MUNOZ D P. Differentiating global luminance, arousal and cognitive signals on pupil size and microsaccades [J]. European Journal of Neuroscience, 2021, 54(10): 7560-7574. doi: 10.1111/ejn.15508 [Baidu Scholar]
WANG C A, BAIRD T, HUANG J, et al. Arousal effects on pupil size, heart rate, and skin conductance in an emotional face task [J]. Frontiers in Neurology, 2018, 9: 1029. doi: 10.3389/fneur.2018.01029 [Baidu Scholar]
CHEN J T, KUO Y C, HSU T Y, et al. Fatigue and arousal modulations revealed by saccade and pupil dynamics [J]. International Journal of Environmental Research and Public Health, 2022, 19(15): 9234. doi: 10.3390/ijerph19159234 [Baidu Scholar]
王丹力,杨心盼,岳康,等. 基于ECG的立体3D显示视疲劳的评估和建模[J]. 系统仿真学报,2019,31(2):212-217. doi: 10.16182/j.issn1004731x.joss.17DEA-003 [Baidu Scholar]
WANG D L, YANG X P, YUE K, et al. Evaluation and modeling of visual fatigue in 3D display based on ECG [J]. Journal of System Simulation, 2019, 31(2): 212-217. (in Chinese). doi: 10.16182/j.issn1004731x.joss.17DEA-003 [Baidu Scholar]
ZHANG Y, TU Y, WANG L L, et al. Assessment of visual fatigue under LED tunable white light with different blue components [J]. Journal of the Society for Information Display, 2020, 28(1): 24-35. doi: 10.1002/jsid.866 [Baidu Scholar]
RAMADAN M Z, ALHAAG M H. Evaluating the user physical stresses associated with watching 3D and 2D displays over extended time using heart rate variability, galvanic skin resistance, and performance measure [J]. Journal of Sensors, 2018, 2018: 2632157. doi: 10.1155/2018/2632157 [Baidu Scholar]
SERIES B T. Methodology for the subjective assessment of the quality of television pictures [R]. Recommendation ITU-R BT.500-13, Geneva: ITU, 2012. [Baidu Scholar]
卢谢峰,唐源鸿,曾凡梅. 效应量:估计、报告和解释[J]. 心理学探新,2011,31(3):260-264. doi: 10.3969/j.issn.1003-5184.2011.03.014 [Baidu Scholar]
LU X F, TANG Y H, ZENG F M. Effect size: estimation, reporting and interpretation [J]. Psychological Exploration, 2011, 31(3): 260-264. (in Chinese). doi: 10.3969/j.issn.1003-5184.2011.03.014 [Baidu Scholar]
王琼华,潘冬冬,李小方,等. 自由立体显示器观看者瞳孔直径与视疲劳关系[J]. 光子学报,2011,40(3):350-353. doi: 10.3788/gzxb20114003.0350 [Baidu Scholar]
WANG Q H, PAN D D, LI X F, et al. Relation between viewer′s pupil diameter and visual fatigue in autostereoscopic display [J]. Acta Photonica Sinica, 2011, 40(3): 350-353. (in Chinese). doi: 10.3788/gzxb20114003.0350 [Baidu Scholar]
PARK S I, WHANG M C, KIM J W, et al. Autonomic nervous system response affected by 3D visual fatigue evoked during watching 3D TV [J]. Science of Emotion and Sensibility, 2011, 14(4): 653-662. [Baidu Scholar]
MINKIN V. Vibraimage, Cybernetics and Emotions [M]. St. Petersburg: Renome, 2020. [Baidu Scholar]
0
Views
360
Downloads
0
CSCD
Related Articles
Related Author