In order to achieve high-resolution 3D integral imaging
an integrated imaging system is designed based on high-resolution image capture by the digital camera arrays and reproduced by the microlens arrays. The resolutions of the integral imaging on real/virtual display modes and display depth is analyzed.Based on the integrated imaging principle
a digital camera is used for high resolution image acquisition.The display resolution and depth are calculated according to the microlens array pitch
focal length
object distance and other parameters.After image processing
the image is printed with high precision.Then the image and the microlens array are glued together.The shooting parameters and display parameters are given.The image contrasts are compared between the traditional parallax display mode and the focus display mode of integrated imaging.In the case of parameters match well
the high-resolution 3D displays are achieved. The resolution of the images
which is near by the central depth plane of real/virtual display mode
can achieve the best.The experimental results prove that the image display effects are excellent in the depth range
the resolution of the real/virtual display mode is much better than that of the focus mode and the traditional multi-view free stereo display
which is based on the parallax principle.
关键词
Keywords
references
Lippmann G. La Photograhie integrale[J].Comptes Rendus Acad. Sci, 1908, 146: 446-451.[2] Park J H, Hong K, Lee B.Recent progress in three-dimensional information processing based on integral imaging[J].Appl.Opt, 2009, 48(34):77-94.[3] Cho M, Daneshpanah M, Javidi B.Three-dimensional optical sensing and visualization using integral imaging[J]. Proc.IEE, 2011, 99(4):556-575.[4] 王琼华.3D显示技术与器件[M]. 北京:科学出版社, 2011:219-224. Wang Q H, 3D Display Technologies and Devices[M].Beijing: Science Press, 2011: 219-224.(in Chinese)[5] Deng H, Wang Q H, Li D H. Method of generating orthoscopic elemental image array from sparse camera array[J].Chinese Optics Letters, 2012, 10(6):061102(1-3).[6] Park J H, Jung S, Choi H, et al. Integral imaging with multiple image planes using a uniaxial crystal plate[J].Opt. Express, 2003, 11(16):1862-1875.[7] Shin D H, Yoo H. Image quality enhancement in 3D computational integral imaging by use of interpolation methods[J].Optics Express, 2007, 15 (19):12039-12049.[8] Lee B, Park Jae-Hyeung, Min Sung-Wook. Three-dimensional display and information processing based on integral imaging[C]//Digital Holography and Three-Dimensional Display, US: Springer, 2006:333-378.[9] Kim Y, Park J H, Choiet H, et al.Depth-enhanced three-dimensional integral imaging by use of multilayered display devices[J].Appl. Opt, 2006, 45(1): 4334-4343.[10] Zitnick C L, Jojic N, Kang S B.Consistent segmentation for optical flow estimation[C]//Proc.IEEE Int.Conf.Computer Vision, US:Springor, 2005:1308-1315.[11] 郝敦博, 李大海, 王琼华, 等. 柱面透镜自由立体显示器的分辨率损失研究[J]. 液晶与显示, 2008, 23(4):494-498. Hao D B, Li D H, Wang Q H, et al.Resolution loss of autostereoscopic display based on lenticular[J].Chinese Journal of Liquid Crystals and Display, 2008, 23(4): 494-498. (in Chinese)
Characterization and compensation of position errors of macro lens array in large-format integral imaging system
Influence of exposure process on the clarity of blue phase liquid crystal patterns
Three-dimensional display method of optical phase based on Hartmann wavefront sensor
Generation of elemental image arrays for different reconstruction depths
Related Author
Zhan YAN
Xin-lei LIU
Tao JING
Ying-qing HUANG
Xiao-yu JIANG
Xing-peng YAN
Yan MAO
MAO Yan
Related Institution
Department of Information Communication, Army Academy of Armored Forces
Department of Information Communication, Army Academy of Armored Forces
School of Science, Hebei University of Technology
Institute of Mathematics and Physics, Beijing Union University
Jiangsu Key Laboratory of Micro and Nano Heat Fluid Flow Technology and Energy Application, School of Physical Science and Technology, Suzhou University of Science and Technology